Glucose Monitoring Devices
eBook - ePub

Glucose Monitoring Devices

Measuring Blood Glucose to Manage and Control Diabetes

Chiara Fabris,Boris Kovatchev

  1. 384 Seiten
  2. English
  3. ePUB (handyfreundlich)
  4. Über iOS und Android verfügbar
eBook - ePub

Glucose Monitoring Devices

Measuring Blood Glucose to Manage and Control Diabetes

Chiara Fabris,Boris Kovatchev

Angaben zum Buch
Buchvorschau
Inhaltsverzeichnis
Quellenangaben

Über dieses Buch

Glucose Monitoring Devices: Measuring Blood Glucose to Manage and Control Diabetes presents the state-of-the-art regarding glucose monitoring devices and the clinical use of monitoring data for the improvement of diabetes management and control. Chapters cover the two most common approaches to glucose monitoring–self-monitoring blood glucose and continuous glucose monitoring–discussing their components, accuracy, the impact of use on quality of glycemic control as documented by landmark clinical trials, and mathematical approaches. Other sections cover how data obtained from these monitoring devices is deployed within diabetes management systems and new approaches to glucose monitoring.

This book provides a comprehensive treatment on glucose monitoring devices not otherwise found in a single manuscript. Its comprehensive variety of topics makes it an excellent reference book for doctoral and postdoctoral students working in the field of diabetes technology, both in academia and industry.

  • Presents a comprehensive approach that spans self-monitoring blood glucose devices, the use of continuous monitoring in the artificial pancreas, and intraperitoneal glucose sensing
  • Provides a high-level descriptions of devices, as well as detailed mathematical descriptions of methods and techniques
  • Written by experts in the field with vast experience in the field of diabetes and diabetes technology

Häufig gestellte Fragen

Wie kann ich mein Abo kündigen?
Gehe einfach zum Kontobereich in den Einstellungen und klicke auf „Abo kündigen“ – ganz einfach. Nachdem du gekündigt hast, bleibt deine Mitgliedschaft für den verbleibenden Abozeitraum, den du bereits bezahlt hast, aktiv. Mehr Informationen hier.
(Wie) Kann ich Bücher herunterladen?
Derzeit stehen all unsere auf Mobilgeräte reagierenden ePub-Bücher zum Download über die App zur Verfügung. Die meisten unserer PDFs stehen ebenfalls zum Download bereit; wir arbeiten daran, auch die übrigen PDFs zum Download anzubieten, bei denen dies aktuell noch nicht möglich ist. Weitere Informationen hier.
Welcher Unterschied besteht bei den Preisen zwischen den Aboplänen?
Mit beiden Aboplänen erhältst du vollen Zugang zur Bibliothek und allen Funktionen von Perlego. Die einzigen Unterschiede bestehen im Preis und dem Abozeitraum: Mit dem Jahresabo sparst du auf 12 Monate gerechnet im Vergleich zum Monatsabo rund 30 %.
Was ist Perlego?
Wir sind ein Online-Abodienst für Lehrbücher, bei dem du für weniger als den Preis eines einzelnen Buches pro Monat Zugang zu einer ganzen Online-Bibliothek erhältst. Mit über 1 Million Büchern zu über 1.000 verschiedenen Themen haben wir bestimmt alles, was du brauchst! Weitere Informationen hier.
Unterstützt Perlego Text-zu-Sprache?
Achte auf das Symbol zum Vorlesen in deinem nächsten Buch, um zu sehen, ob du es dir auch anhören kannst. Bei diesem Tool wird dir Text laut vorgelesen, wobei der Text beim Vorlesen auch grafisch hervorgehoben wird. Du kannst das Vorlesen jederzeit anhalten, beschleunigen und verlangsamen. Weitere Informationen hier.
Ist Glucose Monitoring Devices als Online-PDF/ePub verfügbar?
Ja, du hast Zugang zu Glucose Monitoring Devices von Chiara Fabris,Boris Kovatchev im PDF- und/oder ePub-Format sowie zu anderen beliebten Büchern aus Biological Sciences & Biotechnology. Aus unserem Katalog stehen dir über 1 Million Bücher zur Verfügung.

Information

Jahr
2020
ISBN
9780128168844
section 1
Self-monitoring of blood glucose (SMBG) devices
Chapter 1

Introduction to SMBG

Darja Smigoc Schweiger, MD, PhD, and Tadej Battelino, MD, PhD Department of Endocrinology, Diabetes and Metabolism, University children's hospital University Medical Centre Ljubljana, Ljubljana, Slovenia Faculty of Medicine, University of Ljubljana, Ljubljana, Slovenia

Abstract

Self-monitoring of blood glucose (SMBG), over its half a century of clinical use, gradually developed into an evidence-based standard of care in the management of insulin therapy in both type 1 and type 2 diabetes. The chapter discusses the historical aspects of SMBG development and gradual accumulation of clinical evidence for its efficacy in improving metabolic control and reducing hypoglycemia in insulin-treated diabetes, culminating in landmark clinical trials demonstrating that intensive insulin therapy informed by SMBG delays and/or prevents chronic complications of diabetes. Additionally, data on the use of SMBG in noninsulin-treated diabetes are presented. Finally, current clinical guidelines for different populations of people with diabetes are discussed.

Keywords

Glycated hemoglobin A1c; Hypoglycemia; Insulin therapy; Metabolic control; Self-monitoring of blood glucose; Type 1 diabetes mellitus; Type 2 diabetes mellitus

Historical perspective and principles of blood glucose control

As Benedict developed a copper reagent for urine glucose, urine glucose testing has been the main method for diabetes monitoring for 50 years [1]. Later, a more convenient and specific “dip-and-read” urine glucose oxidase-based reagent strip (Clinistix) was introduced [2]. However, urine tests had several well-recognized limitations. High glucose levels were detected only when the renal threshold for glucose was exceeded over a period of several hours and the results were affected by fluid intake and urine concentration. Moreover, the test did not detect low glucose levels [3]. In the 1960s, first blood glucose (BG) test strips (Dextrostix) were developed. The exposure to blood resulted in a colorimetric reaction proportional to blood glucose concentration. The color change that occurred was compared to a color chart providing a semiquantitative assessment of blood glucose levels [4]. The first blood glucose meter, the Ames Reflectance Meter, was introduced in 1970. The meter exhibited quantitative blood glucose results based on Dextrostix test strips and reflectance photometry, thus eliminating visual reading errors. The results were displayed by a moving pointer on three analog scales [5]. The device was only available for testing in a doctor's office and hospital emergency departments [6]. Although the meter was heavy, expensive, and cumbersome to use, it ushered the development in an era of blood glucose monitoring systems. In 1972, more convenient Eyetone glucometer using Dextrostix test strips was developed, which was more precise, lighter, and easier to operate [7]. In 1974, Boehringer Mannheim launched Reflomat, a reflectance meter with modified reagent test strips (Reflotest), equipped to accept smaller volumes of blood, which was removed more easily and thus more suitable for at-home self-monitoring of blood glucose (SMBG) [6]. Dextrometer and Glucochek launched, in 1980, were the first glucometers with digital display [8]. Technological advances during 1980s made glucometers smaller and easier to use with built-in software to store and retrieve results [6]. The One Touch meter introduced in 1987 was regarded as the first second-generation blood glucose meter because it utilized an improved sampling procedure that eliminated blood removal step and the need for time reactions [9]. Toward the end of the 1980s, test strips changed dramatically when electrochemical principles to measure blood glucose were introduced. Furthermore, the introduction of electrochemical technology led to the development of the third generation of glucose monitoring systems [10]. The landmark in glucose self-monitoring was the release of the first electrochemical blood glucose monitor, ExacTech by Medisense, in 1987. The device used an enzyme electrode strip containing glucose oxidase and ferrocene as an electron transfer mediator. A current generated at the electrode was detected by an amperometric sensor [11].
Today, most glucometers are electrochemical, using commercial screen-printed strips based on the same principle. They require a smaller blood sample and provide results in a few seconds. Glucose oxidase and glucose dehydrogenase are two types of enzymes that have been used for commercial electrochemical blood glucose test strips. Test strips using glucose oxidase technology are susceptible to dissolved oxygen concentrations and can only be used with capillary blood in a normal range of oxygen levels. Glucose dehydrogenase-based test strips are not sensitive to oxygen [12]. However, coenzyme pyrroloquinoline quinone and glucose dehydrogenase containing test strips lack specificity as they cross-react with maltose, galactose, and xylose. Therefore they must not be used by patients on peritoneal dialysis [13]. The most common electrochemical detection methods for glucose measurement are amperometry and coulometry [12]. Coulometric strips have demonstrated to operate over the wider ranges of hematocrit values and with the minimized effect of temperature, high concentrations of paracetamol, uric acid, and vitamin C [14]. The performance of glucometers has further improved with simplified sampling and testing procedures to minimize user interaction errors. Meters using no-coding technology are precalibrated to report whole blood or plasma equivalent results [15]. Most current meters are plasma calibrated and automatically convert results into plasma equivalent results [16]. Modern electrochemical blood glucose test strips use the capillary gap to automatically draw blood into the test surface, which requires only a small volume of blood (just about 0.3 μL) and has automatic...

Inhaltsverzeichnis

  1. Cover image
  2. Title page
  3. Table of Contents
  4. Copyright
  5. Contributors
  6. About the Authors
  7. section 1. Self-monitoring of blood glucose (SMBG) devices
  8. section 2. Continuous glucose monitoring (CGM) devices
  9. section 3. Clinical use of monitoring data
  10. Index
Zitierstile für Glucose Monitoring Devices

APA 6 Citation

Fabris, C., & Kovatchev, B. (2020). Glucose Monitoring Devices ([edition unavailable]). Elsevier Science. Retrieved from https://www.perlego.com/book/1814291/glucose-monitoring-devices-measuring-blood-glucose-to-manage-and-control-diabetes-pdf (Original work published 2020)

Chicago Citation

Fabris, Chiara, and Boris Kovatchev. (2020) 2020. Glucose Monitoring Devices. [Edition unavailable]. Elsevier Science. https://www.perlego.com/book/1814291/glucose-monitoring-devices-measuring-blood-glucose-to-manage-and-control-diabetes-pdf.

Harvard Citation

Fabris, C. and Kovatchev, B. (2020) Glucose Monitoring Devices. [edition unavailable]. Elsevier Science. Available at: https://www.perlego.com/book/1814291/glucose-monitoring-devices-measuring-blood-glucose-to-manage-and-control-diabetes-pdf (Accessed: 15 October 2022).

MLA 7 Citation

Fabris, Chiara, and Boris Kovatchev. Glucose Monitoring Devices. [edition unavailable]. Elsevier Science, 2020. Web. 15 Oct. 2022.