Renewable Power and Energy, Volume II
eBook - ePub

Renewable Power and Energy, Volume II

Wind and Thermal Systems

Gary D. Price

  1. 138 Seiten
  2. English
  3. ePUB (handyfreundlich)
  4. Über iOS und Android verfügbar
eBook - ePub

Renewable Power and Energy, Volume II

Wind and Thermal Systems

Gary D. Price

Angaben zum Buch
Buchvorschau
Inhaltsverzeichnis
Quellenangaben

Über dieses Buch

Photovoltaic power systems are becoming a significant source of energy in our energy resource mix today. It is essential these systems are reliable, safe and secure.

Precise engineering design is required to insure these new power systems meet these requirements. In particular, interconnected systems with existing utility power systems must operate in synchronism and improve overall quality of the electrical power grid.

This book is intended to identify and explain engineering procedures for the design and operation of photovoltaic systems. It includes a review of conventional electrical power systems as implemented in the United States and common to all electrical systems throughout the world and introduces other types of renewable energy systems. The heart of the book is focused on the design of interconnected and stand-alone PV systems–battery storage is becoming an integral part of PV systems, and a significant portion of the text is dedicated to energy storage for stand-alone and back-up power systems. The author also highlights how economics and structural considerations are an essential part of the engineering design process.

Häufig gestellte Fragen

Wie kann ich mein Abo kündigen?
Gehe einfach zum Kontobereich in den Einstellungen und klicke auf „Abo kündigen“ – ganz einfach. Nachdem du gekündigt hast, bleibt deine Mitgliedschaft für den verbleibenden Abozeitraum, den du bereits bezahlt hast, aktiv. Mehr Informationen hier.
(Wie) Kann ich Bücher herunterladen?
Derzeit stehen all unsere auf Mobilgeräte reagierenden ePub-Bücher zum Download über die App zur Verfügung. Die meisten unserer PDFs stehen ebenfalls zum Download bereit; wir arbeiten daran, auch die übrigen PDFs zum Download anzubieten, bei denen dies aktuell noch nicht möglich ist. Weitere Informationen hier.
Welcher Unterschied besteht bei den Preisen zwischen den Aboplänen?
Mit beiden Aboplänen erhältst du vollen Zugang zur Bibliothek und allen Funktionen von Perlego. Die einzigen Unterschiede bestehen im Preis und dem Abozeitraum: Mit dem Jahresabo sparst du auf 12 Monate gerechnet im Vergleich zum Monatsabo rund 30 %.
Was ist Perlego?
Wir sind ein Online-Abodienst für Lehrbücher, bei dem du für weniger als den Preis eines einzelnen Buches pro Monat Zugang zu einer ganzen Online-Bibliothek erhältst. Mit über 1 Million Büchern zu über 1.000 verschiedenen Themen haben wir bestimmt alles, was du brauchst! Weitere Informationen hier.
Unterstützt Perlego Text-zu-Sprache?
Achte auf das Symbol zum Vorlesen in deinem nächsten Buch, um zu sehen, ob du es dir auch anhören kannst. Bei diesem Tool wird dir Text laut vorgelesen, wobei der Text beim Vorlesen auch grafisch hervorgehoben wird. Du kannst das Vorlesen jederzeit anhalten, beschleunigen und verlangsamen. Weitere Informationen hier.
Ist Renewable Power and Energy, Volume II als Online-PDF/ePub verfügbar?
Ja, du hast Zugang zu Renewable Power and Energy, Volume II von Gary D. Price im PDF- und/oder ePub-Format sowie zu anderen beliebten Büchern aus Tecnología e ingeniería & Recursos de energía renovable. Aus unserem Katalog stehen dir über 1 Million Bücher zur Verfügung.
CHAPTER 1
CONVENTIONAL ELECTRIC POWER SYSTEMS
Power and energy are important concepts that must be understood before beginning to explore the application of renewable energy systems. For example, a common misunderstanding is the confusion between watt and watt-hour. Watt is a power term, and watt-hour is an energy term. Adding to the confusion are shortcuts used by the power industry professionals who frequently use the power term megawatt when they really mean megawatt-hour (energy). A utility energy trader will almost universally use the term megawatt when buying or selling a megawatt-hour of energy. We begin this book with definitions and the relationship between energy and power, as used by electrical power engineers.
1.1 POWER ENGINEERING CONCEPTS AND TERMINOLOGY
Power is defined as the time rate at which work is done or energy emitted or transferred. Energy is the capacity for doing work. Watt is a unit of power equal to 1 joule per second—or in electric terms, 1 ampere under the pressure of 1 volt. (joule is the unit of mechanical power equal to a meter-kilogram-second or 0.7375 foot pounds). The important fact to remember from these definitions is that power is a rate, and energy is a quantity. Therefore a watt (w) is the rate at which energy is being produced or transferred. A watt-hour (wh) is the quantity of energy transferred or produced.
Electrical power equipment is typically rated in terms of watts. A 100-watt light bulb will use 100 watt-hours of energy when operated for 1 hour at 1 amp and 100 volts. A photovoltaic (PV) panel rated at 100 watts will generate 100 watt-hours in one hour when operated at a specified solar intensity and connected to an appropriate load. If these devices operate for 6 minutes, the resulting energy will be 10 watt-hours. A kilowatt (kW) is 1,000 watts, a megawatt (MW) is 106 watts, and a gigawatt (GW) is 109 watts.
Power plant generators usually are operated at a constant power near the nameplate rating. This makes it simpler for dispatch operators to communicate by referring to 100 MW and assuming the generator will operate at 100 MW for one hour to produce a 100-MWh block of energy. We cannot make that assumption with PV systems or wind generators because the output power is variable. Wind and solar power must be integrated over time to determine energy.
The British thermal unit (BTU) is a common measure of energy. One BTU is equal to the energy required to heat 1 pound (lb) of water 1 degree Fahrenheit (1°F). A BTU is also equal to 0.293 watt-hours (wh), and 3,412 BTUs equal 1 kWh. The BTU provides a useful conversion between electrical and solar thermal systems. The gas industry commonly uses the acronym MBTU to represent 1,000 BTUs and MMBTU to represent 1,000,000 BTUs. (The M is derived from the Roman numeral value.) This textbook will avoid using MBTU, as it causes frequent calculation errors and confusion. K represents 1,000 and M equals 1,000,000, as used in kW and MW.
A common energy term used in the natural gas industry is the therm. One therm equals 100,000 BTUs and represents the heat or energy content of natural gas. A cubic foot (cu ft) of natural gas contains approximately 0.9 therms of energy. The energy content of natural gas is not consistent, depending on the chemical makeup of natural gas. Natural gas consists of several components: primarily methane, heptane, and propane. Small amounts of nitrogen, carbon dioxide, oxygen, and an odorant are also present in natural gas. The energy content varies from source to source. The energy content also depends on the delivery pressure. The price of natural gas that shows up in our utility bill is usually expressed in dollars per therm.
As aforementioned, a joule is equal to 0.7375 foot-pounds (ft-lbs), and a joule per second is equal to 1 watt. From these relationships, we can determine that 1 kWh of energy is equal to 2,655,000 ft-lbs. If a 150-pound person climbs a 17,700-foot mountain, the amount of energy expended is about 1 kWh! Most of us use that amount of energy for home lighting every day! Another reference to the value of 1 kWh is the content of energy in petroleum: approximately 3 ounces of oil contains 1 kWh of energy if we assume 1 gallon of oil contains 143,300 BTUs. By comparison, if we install 2 square meters (m2) of PV on our roof, the array will generate about 1 kWh of electricity per day.1
Demand is defined as the amount of work to perform a desired function. In the electrical world, the term demand is used to measure the peak power required to operate all connected loads for a particular circuit. If a circuit consists of five 100-watt light bulbs, the peak demand is 500 watts. Demand is determined when the load is at maximum, or when all five lights are on. As utilities are concerned with the maximum load on their system, they measure peak energy in a specified time interval for demand. An instantaneous value is not as significant as the average value during this time interval, usually 15 minutes. For example, if the power on a circuit ranges from 5 to 15 kW during the 15-minute interval, the demand will be about 10 kW. The average value of 10 kW is more significant than the 15 kW peak value, because it more accurately represents the load that the generators must meet.
Capacity is the instantaneous ability to provide energy required to do work. Again, the electrical use of the term capacity usually refers to the size of the generator(s) required to maintain a circuit load. A 100-MW generator will provide the energy required to operate 100 MW of peak load. Capacity is also used to define the load capability of other electrical equipment on the system. A 115-kilovolt (kV) transmission line may safely transfer 100 MW of power without overheating and sagging. A 100-megavolt-ampere (MVA) transformer may safely transform 90 MW of power before it overheats. The safe operating rating of the equipment defines its capacity.
Using the electrical definitions of capacity and demand, energy can be defined as the demand times time-in-use (D × t), or capacity times time-in-use (C × t). These definitions are used when calculating the total consumption. For example, the United States consumed about 4 trillion kWh of energy in 2005.2 That equates to about 13 MWh per year per person. The peak electrical demand for the United States is about 760 GW.
When scientists talk about global or national energy use, the term quad is frequently used. A quad is equal to one quadrillion BTUs. A quad is also approximately equal to the energy stored in 180 million barrels of crude oil. One quad equals 293 billion kWh. The total global primary energy production in 2004 was 446 quads.
Avoided costs are the incremental costs to an electric utility to generate electrical energy. These costs generally include fuel costs for generation, operational costs of transmission, and operational distribution costs per kWh. Fixed costs (e.g., capital equipment improvements, and franchise fees) are not included in avoided costs.
Net metering generally refers to buying and selling energy at the same rate. Net metering applies to small (<10 kW) systems, where the financial impact is relatively negligible to the utility. Under net metering rules, a renewable energy (RE) system is allowed to sell its generated energy at the same rate it is buying energy from the utility. However, utilities and public utility commissions set rules for net metering, which vary by jurisdiction. The utility may require the renewable energy entity to pay avoided costs for excess energy generated each month. More commonly, the utility will pay avoided costs for excess generation at the end of the year. Xcel Energy current...

Inhaltsverzeichnis

  1. Cover
  2. Half-title Page
  3. Title Page
  4. Copyright
  5. Contents
  6. List of Figures
  7. List of Tables
  8. Preface
  9. 1 Conventional Electric Power Systems
  10. 2 Renewable Energy Technologies
  11. 3 The Wind Resource
  12. 4 Wind Generator Systems
  13. 5 Energy Storage and Standalone Wind Systems
  14. 6 Economics
  15. 7 Solar Thermal Systems
  16. Appendix A: Glossary
  17. Appendix B: Colorado net Metering Rules
  18. Appendix C: Acronyms and Abbreviations
  19. Appendix D: Table of Conversions
  20. About the Author
  21. Index
  22. Backcover
Zitierstile für Renewable Power and Energy, Volume II

APA 6 Citation

Price, G. (2018). Renewable Power and Energy, Volume II ([edition unavailable]). Momentum Press. Retrieved from https://www.perlego.com/book/785291/renewable-power-and-energy-volume-ii-wind-and-thermal-systems-pdf (Original work published 2018)

Chicago Citation

Price, Gary. (2018) 2018. Renewable Power and Energy, Volume II. [Edition unavailable]. Momentum Press. https://www.perlego.com/book/785291/renewable-power-and-energy-volume-ii-wind-and-thermal-systems-pdf.

Harvard Citation

Price, G. (2018) Renewable Power and Energy, Volume II. [edition unavailable]. Momentum Press. Available at: https://www.perlego.com/book/785291/renewable-power-and-energy-volume-ii-wind-and-thermal-systems-pdf (Accessed: 14 October 2022).

MLA 7 Citation

Price, Gary. Renewable Power and Energy, Volume II. [edition unavailable]. Momentum Press, 2018. Web. 14 Oct. 2022.