Personnel Protection and Safety Equipment for the Oil and Gas Industries
eBook - ePub

Personnel Protection and Safety Equipment for the Oil and Gas Industries

Alireza Bahadori

Partager le livre
  1. 598 pages
  2. English
  3. ePUB (adapté aux mobiles)
  4. Disponible sur iOS et Android
eBook - ePub

Personnel Protection and Safety Equipment for the Oil and Gas Industries

Alireza Bahadori

DĂ©tails du livre
Aperçu du livre
Table des matiĂšres
Citations

À propos de ce livre

Oil and gas companies are repeatedly cited by regulatory organizations for poor training and maintenance on providing personal protective equipment to their refinery workers. Managers of refinery and petrochemical plants are responsible for instructing their workers with the types of equipment available, how to properly wear the equipment, how to properly care and maintain the equipment, and, most importantly, it's their responsibility to enforce these regulations and safety requirements. While there are many reference materials on the subject, most are too broad to apply directly to the unique and highly volatile atmosphere of an oil and gas operation. Personnel Protection and Safety Equipment for the Oil and Gas Industries answers the call for safety managers onsite as well as workers to understand all the safety equipment available specifically for the energy sector. Condensed into one convenient reference location, this training guide is designed to inform on several types of personnel protective clothing, firefighting protective clothing, respiratory protective devises available as well as many other types of protective equipment, including fall protection and vehicle safety belts and harnesses. Industry-specific examples, multiple illustrations, and a glossary of terms make Personnel Protection and Safety Equipment for the Oil and Gas Industries a must-have on every oil and gas operation.

  • Know recommended US and international protective safety equipment regulations
  • Learn the types, classes, and materials of safety and protective equipment specific to the oil and gas industry
  • Gain knowledge on how to select, test, maintain, and store protective equipment properly

Foire aux questions

Comment puis-je résilier mon abonnement ?
Il vous suffit de vous rendre dans la section compte dans paramĂštres et de cliquer sur « RĂ©silier l’abonnement ». C’est aussi simple que cela ! Une fois que vous aurez rĂ©siliĂ© votre abonnement, il restera actif pour le reste de la pĂ©riode pour laquelle vous avez payĂ©. DĂ©couvrez-en plus ici.
Puis-je / comment puis-je télécharger des livres ?
Pour le moment, tous nos livres en format ePub adaptĂ©s aux mobiles peuvent ĂȘtre tĂ©lĂ©chargĂ©s via l’application. La plupart de nos PDF sont Ă©galement disponibles en tĂ©lĂ©chargement et les autres seront tĂ©lĂ©chargeables trĂšs prochainement. DĂ©couvrez-en plus ici.
Quelle est la différence entre les formules tarifaires ?
Les deux abonnements vous donnent un accĂšs complet Ă  la bibliothĂšque et Ă  toutes les fonctionnalitĂ©s de Perlego. Les seules diffĂ©rences sont les tarifs ainsi que la pĂ©riode d’abonnement : avec l’abonnement annuel, vous Ă©conomiserez environ 30 % par rapport Ă  12 mois d’abonnement mensuel.
Qu’est-ce que Perlego ?
Nous sommes un service d’abonnement Ă  des ouvrages universitaires en ligne, oĂč vous pouvez accĂ©der Ă  toute une bibliothĂšque pour un prix infĂ©rieur Ă  celui d’un seul livre par mois. Avec plus d’un million de livres sur plus de 1 000 sujets, nous avons ce qu’il vous faut ! DĂ©couvrez-en plus ici.
Prenez-vous en charge la synthÚse vocale ?
Recherchez le symbole Écouter sur votre prochain livre pour voir si vous pouvez l’écouter. L’outil Écouter lit le texte Ă  haute voix pour vous, en surlignant le passage qui est en cours de lecture. Vous pouvez le mettre sur pause, l’accĂ©lĂ©rer ou le ralentir. DĂ©couvrez-en plus ici.
Est-ce que Personnel Protection and Safety Equipment for the Oil and Gas Industries est un PDF/ePUB en ligne ?
Oui, vous pouvez accĂ©der Ă  Personnel Protection and Safety Equipment for the Oil and Gas Industries par Alireza Bahadori en format PDF et/ou ePUB ainsi qu’à d’autres livres populaires dans TecnologĂ­a e ingenierĂ­a et Combustibles fĂłsiles. Nous disposons de plus d’un million d’ouvrages Ă  dĂ©couvrir dans notre catalogue.

Informations

1

Breathing apparatus for personnel safety and protection

Atmospheres can be contaminated by dust or gas, or be deficient in oxygen. These hazards can occur singly or in any combination. In this chapter, the term dust includes mist and fume, and gas includes vapor. Each contaminant can have special characteristics of its own that require protection. Contaminated atmospheres are generally described as nuisance atmospheres that are not toxic or immediately dangerous to health, hazardous atmospheres that are of low toxicity or cause easily reversible biological changes, dangerous atmospheres of a high toxicity or where the health hazards are more severe, and atmospheres immediately dangerous to life. This chapter is designed to assist in the selection of respiratory protective devices for use against atmospheric contaminants.

Keywords

Respiratory protective; hazardous atmospheres; dust; self-contained breathing apparatus; air-purifying respirators; toxicity

1.1 Introduction

This chapter is designed to assist in the selection of respiratory protective devices (RPDs) for use against atmospheric contaminants. Atmospheres can be contaminated by dust, gas, or by being deficient in oxygen. These hazards occur singly or in any combination. In this context, dust can include mist and fume and gas can include vapor.
Each contaminant can have special characteristics of its own that require protection in addition to those discussed in this section. For instance, radioactive or corrosive materials require the use of special clothing. Some gases, liquids, and soluble solids absorb through the skin, and these also require special protection.
Contaminated atmospheres are generally described as nuisance atmospheres that are not toxic or immediately dangerous to health, hazardous atmospheres that are of low toxicity or easily cause reversible biological changes, dangerous atmospheres of a high toxicity or where the health hazards are more serious, and atmospheres immediately dangerous to life.
RPDs should either filter the contaminated atmosphere to produce air suitable for respiration, or supply such air from an alternative source. The air is supplied to the breathing area (the nose and mouth of the user) by one of the following: a mouthpiece and nose clip; a half-mask covering the nose and mouth; a full facepiece covering the eyes, nose, and mouth; a hood covering the head down to the shoulders; or a suit covering the head and body down to the waist and wrists.
In this chapter, for each type of RPD a nominal protection factor is given. This factor is a guide to the effectiveness of the device when used correctly. It indicates the degree to which the atmospheric contaminant is reduced by the respirator within the breathing zone. Thus, a device that reduces the level of contamination 10 times will have a nominal protection factor of 10, while one that reduces it 1000 times will have a nominal protection factor of 1000. These figures should be used in conjunction with the maximum allowable concentration, or threshold limit value, of the contaminant and its actual concentration in the atmosphere. Generally, a substance with a threshold limit value of 10 parts per million, which has a concentration of 1000 parts per million in the atmosphere, will require the use of equipment with a nominal protection factor of at least 100.
Breathing apparatus sets allow firefighters to enter areas filled with smoke or other poisonous gases. These sets consist of a cylinder that contains compressed air, a mask that is worn over the whole face, a gauge to tell the firefighter the pressure in the cylinder, a distress signal unit that activates if the firefighter stops moving, and other safety equipment. The cylinder can supply up to 45 minutes of air, although hard work and other factors can reduce this duration. Breathing apparatus (BA) is also available in a twin-cylinder configuration for longer use.
The following requirements will be discussed in more detail in subsequent sections of this chapter.
In the control of occupational diseases caused by breathing air contaminated with harmful dusts, fogs, fumes, mists, gases, smokes, sprays, or vapors, the primary objective is to prevent atmospheric contamination. This is accomplished as far as feasible by accepted engineering control measures (e.g., enclosure or confinement of the operation, general and local ventilation, and substitution with less toxic materials).
Respirators should be provided by employers when such equipment is necessary to protect the health of employees. Employers should provide respirators that are applicable and suitable for the task, and should establish and maintain a respiratory protective program that covers these general requirements.
Employee should use the provided respiratory protection in accordance with the instructions and training received, and should guard against damage to the respirator. Employees should report any malfunction of the respirator.

1.1.1 Minimal acceptable program

Standard operating instructions governing the selection and use of respirators should be observed. Respirators should be selected on the basis of the hazards to which workers are exposed. The user should be instructed and trained in the proper use of respirators and their limitations.
All types of BA should be regularly cleaned and disinfected. Those issued for the exclusive use of one employee should be cleaned after each day’s use, or more often if necessary. Those used by more than one employee should be thoroughly cleaned and disinfected after each use. Appropriate surveillance of work-area conditions and degree of employee exposure or stress should also be maintained. There should be regular checkups and evaluations to determine the continued effectiveness of the program.
The company’s industrial hygiene, health physics, safety engineering, or fire department should administer the program in close liaison with the company’s medical department. Responsibility for the program should be given to one individual to assure it is maintained. In small plants having no formal industrial hygiene, health physics, safety, fire, or medical department, the respirator program should be handled by an upper-level superintendent, foreman, or other qualified individual. The program’s administrator should also have sufficient knowledge to properly supervise the program.

1.1.2 Medical limitations

A firefighter should be assigned tasks requiring use of RPDs only if it has been determined that he is able to perform these tasks while using the device(s). Firefighters with punctured eardrums should wear earplugs. The assigned physician should determine what health, physical, and psychological conditions are pertinent. The firefighter’s medical status pertaining to use of RPDs should be r...

Table des matiĂšres