Imaging of the Cardiovascular System, Thorax, and Abdomen
eBook - ePub

Imaging of the Cardiovascular System, Thorax, and Abdomen

Luca Saba, Luca Saba

  1. 627 pagine
  2. English
  3. ePUB (disponibile sull'app)
  4. Disponibile su iOS e Android
eBook - ePub

Imaging of the Cardiovascular System, Thorax, and Abdomen

Luca Saba, Luca Saba

Dettagli del libro
Anteprima del libro
Indice dei contenuti
Citazioni

Informazioni sul libro

Magnetic resonance imaging (MRI) is a technique used in biomedical imaging and radiology to visualize internal structures of the body. Because MRI provides excellent contrast between different soft tissues, the technique is especially useful for diagnostic imaging of the brain, muscles, and heart.

In the past 20 years, MRI technology has improved significantly with the introduction of systems up to 7 Tesla (7 T) and with the development of numerous post-processing algorithms such as diffusion tensor imaging (DTI), functional MRI (fMRI), and spectroscopic imaging. From these developments, the diagnostic potentialities of MRI have improved impressively with an exceptional spatial resolution and the possibility of analyzing the morphology and function of several kinds of pathology.

Given these exciting developments, the Magnetic Resonance Imaging Handbook: Imaging of the Cardiovascular System, Thorax, and Abdomen is a timely addition to the growing body of literature in the field. Offering comprehensive coverage of cutting-edge imaging modalities, this book:



  • Discusses MRI of the heart, blood vessels, lungs, breasts, diaphragm, liver, gallbladder, spleen, pancreas, adrenal glands, and gastrointestinal tract
  • Explains how MRI can be used in vascular, posttraumatic, postsurgical, and computer-aided diagnostic (CAD) applications
  • Highlights each organ's anatomy and pathological processes with high-quality images
  • Examines the protocols and potentialities of advanced MRI scanners such as 7 T systems
  • Includes extensive references at the end of each chapter to enhance further study

Thus, the Magnetic Resonance Imaging Handbook: Imaging of the Cardiovascular System, Thorax, and Abdomen provides radiologists and imaging specialists with a valuable, state-of-the-art reference on MRI.

Domande frequenti

Come faccio ad annullare l'abbonamento?
È semplicissimo: basta accedere alla sezione Account nelle Impostazioni e cliccare su "Annulla abbonamento". Dopo la cancellazione, l'abbonamento rimarrà attivo per il periodo rimanente già pagato. Per maggiori informazioni, clicca qui
È possibile scaricare libri? Se sì, come?
Al momento è possibile scaricare tramite l'app tutti i nostri libri ePub mobile-friendly. Anche la maggior parte dei nostri PDF è scaricabile e stiamo lavorando per rendere disponibile quanto prima il download di tutti gli altri file. Per maggiori informazioni, clicca qui
Che differenza c'è tra i piani?
Entrambi i piani ti danno accesso illimitato alla libreria e a tutte le funzionalità di Perlego. Le uniche differenze sono il prezzo e il periodo di abbonamento: con il piano annuale risparmierai circa il 30% rispetto a 12 rate con quello mensile.
Cos'è Perlego?
Perlego è un servizio di abbonamento a testi accademici, che ti permette di accedere a un'intera libreria online a un prezzo inferiore rispetto a quello che pagheresti per acquistare un singolo libro al mese. Con oltre 1 milione di testi suddivisi in più di 1.000 categorie, troverai sicuramente ciò che fa per te! Per maggiori informazioni, clicca qui.
Perlego supporta la sintesi vocale?
Cerca l'icona Sintesi vocale nel prossimo libro che leggerai per verificare se è possibile riprodurre l'audio. Questo strumento permette di leggere il testo a voce alta, evidenziandolo man mano che la lettura procede. Puoi aumentare o diminuire la velocità della sintesi vocale, oppure sospendere la riproduzione. Per maggiori informazioni, clicca qui.
Imaging of the Cardiovascular System, Thorax, and Abdomen è disponibile online in formato PDF/ePub?
Sì, puoi accedere a Imaging of the Cardiovascular System, Thorax, and Abdomen di Luca Saba, Luca Saba in formato PDF e/o ePub, così come ad altri libri molto apprezzati nelle sezioni relative a Medicina e Radiologia, radioterapia e medicina nucleare. Scopri oltre 1 milione di libri disponibili nel nostro catalogo.

Informazioni

Editore
CRC Press
Anno
2017
ISBN
9781315356280

1

Coronary and Perfusion Imaging with Cardiovascular Magnetic Resonance: Current State of the Art

Amedeo Chiribiri, Markus Henningsson, Claudia Prieto, Michael Jerosch-Herold and Rene M. Botnar

CONTENTS

1.1 Introduction
1.2 Technical Challenges and General Imaging Strategies for Coronary CMR
1.2.1 Compensation of Cardiac Motion: ECG Triggering
1.2.2 Compensation of Respiratory Motion: Navigator
1.2.3 Coronary Artery Imaging
1.2.3.1 Sequences
1.2.3.2 Contrast-Enhancing Spin Preparations
1.2.3.3 Contrast Agents
1.2.3.4 Recent Improvements in Acquisition Speed and Resolution
1.2.4 Coronary Vein Imaging
1.2.5 Coronary Vessel Wall Imaging
1.2.6 Special Considerations: Intracoronary Stents
1.3 Clinical Applications
1.3.1 Coronary Artery Angiography for the Detection of CAD
1.3.2 Coronary Anomalies and Aneurysms
1.3.3 Coronary Bypass Grafts
1.3.4 Coronary Vessel Wall Imaging
1.3.5 Coronary Vein Imaging
1.4 Myocardial Perfusion Imaging
1.4.1 Techniques for Magnetic Resonance Myocardial Perfusion Imaging
1.4.2 Clinical Applications
1.5 Conclusions—Future Perspective
References

1.1 Introduction

Despite substantial improvements in prevention and treatment,1 coronary artery disease (CAD) remains the leading cause of death and disability in the Western world.2 The current gold standard for the diagnosis of CAD is cardiac catheterization. In the United States alone, 16,300,000 patients are suffering from CAD, and approximately 1,000,000 cardiac catheterizations are performed each year.2 In up to 40% of examined patients, no significant coronary artery stenoses are diagnosed.3 Therefore, a noninvasive test that could directly assess the integrity of the coronary lumen would be desirable.4 Cardiovascular magnetic resonance (CMR) allows a comprehensive evaluation of myocardial function, perfusion, and morphology in patients with CAD.5 In addition, magnetic resonance angiography (MRA) can be used for direct visualization of the coronary artery lumen, whereas black blood techniques allow for visualization of the coronary vessel wall,6 making CMR a tool capable of providing all required diagnostic information in one single examination.
Moreover, the same MRA techniques allow the visualization of the coronary veins anatomy, which is of interest for the optimal placement of pacemaker leads in cardiac resynchronization therapy.7,8
This chapter provides an update on current improvements in coronary MRA as well as an overview on its current clinical usage.

1.2 Technical Challenges and General Imaging Strategies for Coronary CMR

Coronary MRA demands dedicated techniques to optimize image contrast and to ensure a high signal-to-noise ratio (SNR), yielding a clear delineation from blood-filled structures or the vessel walls with high spatial resolution. Since high spatial resolution is required for adequate visualization of the coronary vessels, the concomitant intrinsic cardiac and respiratory motions pose a major challenge to coronary MRA and vessel wall imaging.
To overcome this, a standard coronary MRA protocol comprises (1) electrocardiogram (ECG) triggering for synchronization of the heart motion with the data acquisition, (2) respiratory navigation for synchronization/ compensation of the respiratory motion, (3) the imaging sequence itself, and (4) prepulses for spin preparation to ensure sufficient image contrast (Figure 1.1).

1.2.1 Compensation of Cardiac Motion: ECG Triggering

To freeze cardiac motion, data acquisition has to be synchronized with the cardiac cycle and be limited to periods of minimal cardiac movement.9 Resting periods occur in end-systole (approximately 280–350 ms after the R wave) and in mid-diastole (immediately prior to atrial systole). Both acquisition strategies (systolic or diastolic) have advantages and disadvantages (Table 1.1).
The optimal trigger delay and the length of the acquisition window depends on the patients’ heart rate, on the type of imaging sequence used, on the structure to visualize (arteries versus veins), and other hemodynamic factors. While the use of a heart-rate dependent formula to identify the mid-diastolic resting period is effective in many subjects, there may be considerable intersubject variation.10 Therefore, the resting period should be identified for each patient from a free-breathing high temporal resolution cine scan in the four-chamber view performed shortly before the coronary scan.9 Real-time arrhythmia rejection to exclude irregular heartbeats may further improve coronary MRA image quality.1114
Another important parameter to consider is the duration of the resting period. It is typically longer for the left compared to the right coronary artery system. Thus, the length of the acquisition window of a whole heart acquisition is determined by the duration of RCA diastasis.

1.2.2 Compensation of Respiratory Motion: Navigator

The displacement of the heart due to respiration can exceed 2–3 cm, requiring synchronization of image acquisition with the respiratory cycle. High-resolution three-dimensional (3D) datasets are not compatible with breath-hold acquisitions. Several approaches have been tested to reduce the effect of respiratory motion on image quality. Prospective real-time navigator gating and correction techniques are the current approach to minimize respiratory motion artifacts.15,16 A pencil beam one-dimensional navigator typically positioned on the dome of the right hemidiaphragm is used to monitor the foot head motion17 of the diaphragm immediately prior to coronary image acquisition (Figure 1.2). Depending on the position of the diaphragm, the data is either accepted, when the position falls within a certain acceptance window (usually 3–5 mm), or rejected. In the latter case, the data has to be remeasured in the subsequent cardiac cycle. Reduction of the acceptance window reduces the motion artifacts but increases the overall acquisition time because more data is rejected. An acceptance window of 5 mm usually allows an efficiency approaching 50%.1820
Images
FIGURE 1.1
Schematic representation of pulse sequence elements for MRA. Image acquisition is performed in mid-diastole after a trigger delay from the R wave of the ECG. The imaging block is preceded by a contrast-enhancing spin preparation (T2 PREP), a 2D selective real-time navigator pulse for respiratory motion compensation, and a frequency-selective fat-suppression prepulse (FATSAT). These sequence blocks are repeated with every heart cycle. (Adapted from Botnar, R.M. et al., Circulation, 99, 3139–3148, 1999. With permission.)
TABLE 1.1
Comparison between Systolic and Diastolic Coronary CMR
Diastolic Resting Period
Systolic Resting Period
Advantages
Longer acquisition window (~100–125 ms/heartbeat)
Higher blood flow (higher signal in gradient echo sequences)
Advantages
Less sensitive to heart rate variability
Larger diameter of the venous vessels
Disadvantage
Higher sensitivity to heart rate variability
Disadvantage
Shorter acquisition window (~50 ms/heartbeat)
To increase the percentage of accepted data, the position of the imaging slice can be prospectively adapted to the measured respiratory position. Normally the movement of the heart due to breathing is less pronounced than the motion of the diaphragm itself, and a scale factor between 0.4 and 0.6 has been used for optimal slice tracking. However, also with the use of these techniques, respiratory induced motion of the heart often cannot be completely modeled by a simple translation along the foot–head direction, and it has been shown that in up to 30% of patients, an affine transformation models the respiratory motion more accurately.21,22
Other proposed approaches include the use of image-based navigators that directly track cardiac motion, navigators that monitor the movement of the epicardial fat,23 scanning in prone position,24,25 and the use of an abdominal or a thoracic banding.25,26

1.2.3 Coronary Artery Imaging

1.2.3.1 Sequences
3D approaches require long acquisition times and were initially not feasible. The first approaches to coronary artery angiography were attempted by Edelman22 and Manning27 by two-dimensional (2D) gradient-echo techniques. One slice was acquired in 16 heartbeats (in a single breath-hold) and patients were free to breathe between acquisitions. The introduction of navigator techniques allowed the acquisition of data in free breathing and 3D techniques became feasible.
Images
FIGURE 1.2
Planning of the navigator and of the whole heart imaging volume from coronal (a) and axial (b) scout images. A pencil beam one-dimensional navigator is posit...

Indice dei contenuti

  1. Cover
  2. Half Title
  3. Title Page
  4. Copyright Page
  5. Dedication
  6. Table of Contents
  7. Preface
  8. Acknowledgments
  9. Editor
  10. Contributors
  11. 1. Coronary and Perfusion Imaging with Cardiovascular Magnetic Resonance: Current State of the Art
  12. 2. Imaging of the Heart: Myocardial Imaging
  13. 3. Computed Topography/Magnetic Resonance Imaging of Pericardial Disease
  14. 4. Vascular Imaging of the Head and Neck
  15. 5. Magnetic Resonance Imaging: Aorta and Splanchnic Vessels
  16. 6. Peripheral Magnetic Resonance Angiography
  17. 7. Magnetic Resonance Venography
  18. 8. Vascular Malformations
  19. 9. Four-Dimensional Flow Imaging
  20. 10. Magnetic Resonance Imaging for Trachea, Bronchi, and Lung
  21. 11. Clinical Magnetic Resonance Imaging Applications for the Lung
  22. 12. Pleura and Diaphragm
  23. 13. Functional Magnetic Resonance Imaging of the Lung and Pulmonary Vasculature
  24. 14. Breast MRI
  25. 15. Liver: Technique and Diffuse Pathology
  26. 16. Liver: Focal Pathology
  27. 17. Gallbladder
  28. 18. Magnetic Resonance Imaging of Biliary Tract
  29. 19. Update in Magnetic Resonance Imaging of the Spleen
  30. 20. Pancreas
  31. 21. The Adrenal Gland
  32. 22. Diseases of the Upper Gastrointestinal Tract and Small Bowel
  33. 23. MRI of the Retroperitoneum
  34. 24. Abdominal Wall and Hernias
  35. 25. Diseases of the Colon and Rectum
  36. 26. Posttraumatic and Postsurgical Abdomen
  37. Index
Stili delle citazioni per Imaging of the Cardiovascular System, Thorax, and Abdomen

APA 6 Citation

[author missing]. (2017). Imaging of the Cardiovascular System, Thorax, and Abdomen (1st ed.). CRC Press. Retrieved from https://www.perlego.com/book/1471565/imaging-of-the-cardiovascular-system-thorax-and-abdomen-pdf (Original work published 2017)

Chicago Citation

[author missing]. (2017) 2017. Imaging of the Cardiovascular System, Thorax, and Abdomen. 1st ed. CRC Press. https://www.perlego.com/book/1471565/imaging-of-the-cardiovascular-system-thorax-and-abdomen-pdf.

Harvard Citation

[author missing] (2017) Imaging of the Cardiovascular System, Thorax, and Abdomen. 1st edn. CRC Press. Available at: https://www.perlego.com/book/1471565/imaging-of-the-cardiovascular-system-thorax-and-abdomen-pdf (Accessed: 14 October 2022).

MLA 7 Citation

[author missing]. Imaging of the Cardiovascular System, Thorax, and Abdomen. 1st ed. CRC Press, 2017. Web. 14 Oct. 2022.