Power Electronic Converters for Microgrids
eBook - ePub

Power Electronic Converters for Microgrids

  1. English
  2. ePUB (mobile friendly)
  3. Available on iOS & Android
eBook - ePub
Book details
Book preview
Table of contents
Citations

About This Book

As concerns about climate change, energy prices, and energy security loom, regulatory and research communities have shown growing interest in alternative energy sources and their integration into distributed energy systems. However, many of the candidate microgeneration and associated storage systems cannot be readily interfaced to the 50/60 Hz grid. In Power Electronic Converters for Microgrids, Sharkh and Abu-Sara introduce the basics and practical concerns of analyzing and designing such micro-generation grid interface systems. Readers will become familiar with methods for stably feeding the larger grid, importing from the grid to charge on-site storage, disconnecting from the grid in case of grid failure, as well as connect multiple microgrids while sharing their loads appropriately. Sharkh and Abu-Sara introduce not only the larger context of the technology, but also present potential future applications, along with detailed case studies and tutorials to help the reader effectively engineer microgrid systems.

Frequently asked questions

Simply head over to the account section in settings and click on ā€œCancel Subscriptionā€ - itā€™s as simple as that. After you cancel, your membership will stay active for the remainder of the time youā€™ve paid for. Learn more here.
At the moment all of our mobile-responsive ePub books are available to download via the app. Most of our PDFs are also available to download and we're working on making the final remaining ones downloadable now. Learn more here.
Both plans give you full access to the library and all of Perlegoā€™s features. The only differences are the price and subscription period: With the annual plan youā€™ll save around 30% compared to 12 months on the monthly plan.
We are an online textbook subscription service, where you can get access to an entire online library for less than the price of a single book per month. With over 1 million books across 1000+ topics, weā€™ve got you covered! Learn more here.
Look out for the read-aloud symbol on your next book to see if you can listen to it. The read-aloud tool reads text aloud for you, highlighting the text as it is being read. You can pause it, speed it up and slow it down. Learn more here.
Yes, you can access Power Electronic Converters for Microgrids by Suleiman M. Sharkh, Mohammad A. Abu-Sara, Georgios I. Orfanoudakis, Babar Hussain in PDF and/or ePUB format, as well as other popular books in Technology & Engineering & Power Resources. We have over one million books available in our catalogue for you to explore.

Information

Chapter 1
Introduction

Fossil fuels are running out and current centralized power generation plants using these fuels are inefficient with a significant amount of energy lost as heat to the environment. These plants also produce harmful emissions and greenhouse gases. Furthermore, existing power systems, especially in developing countries, suffer from several limitations, such as the high cost of expansion and efficiency improvement limits within the existing grid infrastructure. Renewable energy sources can help address these issues, but their variable nature poses challenges to their integration within the grid.
Distributed generators (DGs), including renewable sources, within microgrids can help overcome power system capacity limitations, improve efficiency, reduce emissions, and manage the variability of renewable sources. A microgrid, a relatively new concept, is a zone within the main grid where a cluster of electrical loads and small microgeneration systems, such as solar cells, fuel cells, wind turbine, and small combined heat and power (CHP) systems, exist together under an embedded management and control system, with the option of energy storage. Other benefits of generating power close to electrical loads include the use of waste heat locally, saving the cost of upgrading the grid to supply more power from central plants, reducing transmission losses, and creating opportunities for increasing competition in the sector, which can stimulate innovation and reduce consumer prices [1, 2].
Power electronic converters are used in microgrids to control the flow of power and convert it into suitable DC or AC form. Different types of converter are needed to perform the many functions within a microgrid, but it is not the aim of this chapter or this book to review all of these possible types of converter, many of which are covered in textbooks and other publications [3]. The book will primarily focus on converters used to connect DG systems, including microCHP and renewable energy sources, to an AC grid or to local AC loads, as illustrated in Figure 1.1. They convert DC (from photovoltaic cells [4], batteries, fuel cells [5]) or variable frequency AC (wind and marine turbine [6]) into 50/60 Hz AC power that is injected into the grid and/or used to supply local loads. Converters are also used to connect flywheel energy storage systems or high-speed microturbine generators to the grid.
c01f001
Figure 1.1 A schematic diagram of a microgrid

1.1 Modes of Operation of Microgrid Converters

Normally, converters are used to connect DG systems in parallel with the grid or other sources, but it may be useful for the converters to continue functioning in stand-alone mode when the other sources become unavailable, in order to supply critical loads. Converters connected to batteries or other storage devices will also need to be bidirectional to charge and discharge these devices.

1.1.1 Grid Connection Mode

In this mode of operation, the converter connects the power source in parallel with other sources to supply local loads and possibly feed power into the main grid. Parallel connection of embedded generators is governed by national standards [7ā€“9]. The standards require that the embedded generator should not regulate or oppose the voltage at the point of common coupling, and that the current fed into the grid should be of high quality with upper limits on its total harmonic distortion (THD). There is also a limit on the maximum DC current injected into the grid.
The power injected into the grid can be controlled either by direct control of the current fed into the grid [10] or by controlling the power angle [11]. In the latter case, the voltage is controlled to be sinusoidal. However, using power angle control without directly controlling the output current may not be effective at reducing the output current THD when the grid voltage is highly distorted. But this is also an issue in the case of electric machine generators which effectively use power angle control. This raises the question of whether it is reasonable to specify current THD limits, regardless of the quality of the utility voltage.
In practice, the converter output current or voltage needs to be synchronized with the grid, which is usually achieved by using a phase-locked loop or grid voltage zero crossing detection [12]. The standards also require that embedded generators, including power electronic converters, should incorporate an anti-islanding feature, so that they are disconnected from the point of common coupling when the grid power is lost. There are many anti-islanding techniques, the most common being the rate of change of frequency (RoCoF) technique [13].

1.1.2 Stand-Alone Mode

It may be desirable for the converter to continue to supply a critical local load when the main grid is disconnected, for example, by the anti-islanding protection system. In this stand-alone mode the converter needs to maintain constant voltage and frequency, regardless of load imbalance or the quality of the current, which can be highly distorted if the load is nonlinear.
A situation may arise in a microgrid, disconnected from the main grid, where two or more power electronic converters switch to stand-alone mode to supply a critical load. In this case, these converters need to share the load equitably. Equitable sharing of load by parallel connected converters operating in stand-alone mode requires additional control. There are several methods for parallel connection, which can be broadly classified into two categories: (i) frequency and voltage droop method [14] and (ii) master-slave method, whereby one of the converters acts as a master, setting the frequency and voltage, and communicating to the other converters their share of the load [15].

1.1.3 Battery Charging Mode

In a microgrid, storage batteries, or other energy storage devices are needed to handle disturbances and fast load changes [16]. In other words, energy storage is needed to accommodate the variations of available power generation and demand, thus improving the reliability of the microgrid. The power electronic converter could then be used as a battery charger.

1.2 Converter Topologies

Most of the current commercially available power electronic converters used for grid connection are based on the voltage-source two-level PWM (pulse width modulation) inverter, as illustrated in Figure 1.2 [10, 17]. An LCL filter is commonly used, but L filters have been also used [18, 19]. An LCL filter is smaller in size compared to a simple L filter, but it requires a more complex control system to manage the LC resonance. Additionally, the impedance of L2C in Figure 1.2 tends to be relatively low, which provides an easy path for current harmonics to flow from the grid. This can cause the THD of the current to increase beyond permitted limits in cases where the grid voltage THD is relatively high. Ideally, this drawback could be overcome by increasing the feedback controller gain in a current controlled grid connected converter, but this can prove to be difficult to achieve in practice while maintaining good stability [20].
c01f002
Figure 1.2 Twolevel grid-connected inverter with LCL filter
Other filter topologies have also been proposed. For example, Guoqiao et al. [21], proposed an LCCL filter arrangement, feeding back the current measured between the two capacitors. By selecting the values of the capacitors to match the inductor values, the closed loop transfer function of the system becomes non-resonant, which helps to improve the performance of the controller, as discussed in Section1.4.
The size and cost of the filter can be very significant. Filter size can be reduced by either increasing the switching frequency of the converter or reducing the converter voltage step changes. However, the switching frequency, which is limited by losses in the power electronic devices, tends to reduce as the power ratings of the devices and the converters increase. This means that high power two-level converters could have disproportionately large filters.
Alterative converter topologies, which can help reduce the size of the filter, have been the subject of recent research. Multi-level converters have been proposed, in...

Table of contents

  1. Cover
  2. Title Page
  3. Copyright
  4. About the Authors
  5. Preface
  6. Acknowledgments
  7. Chapter 1: Introduction
  8. Chapter 2: Converter Topologies
  9. Chapter 3: DC-Link Capacitor Current and Sizing in NPC and CHB Inverters
  10. Chapter 4: Loss Comparison of Two- and Three-Level Inverter Topologies
  11. Chapter 5: Minimization of Low-Frequency Neutral-Point Voltage Oscillations in NPC Converters
  12. Chapter 6: Digital Control of a Three-Phase Two-Level Grid-Connected Inverter
  13. Chapter 7: Design and Control of a Grid-Connected Interleaved Inverter
  14. Chapter 8: Repetitive Current Control of an Interleaved Grid-Connected Inverter
  15. Chapter 9: Line Interactive UPS
  16. Chapter 10: Microgrid Protection
  17. Chapter 11: An Adaptive Relaying Scheme for Fuse Saving
  18. Appendix A: SVM for the NPC Converterā€“MATLABĀ®-Simulink Models
  19. Appendix B: DC-Link Capacitor Current Numerical Calculation
  20. Index
  21. End User License Agreement